Secure Power Protection - Liebert UPS Run Times


PowerSure       §      UPStation GXT Mini-Tower       §      UPStation GXT2 Rack/Tower       §      Liebert Nfinity       §      Liebert 3 Phase      §      Accessories       §     

 

 

 

 

 

 

 

 

 

 

 

Secure Power Home Page

Our Liebert Home Page

Subscribe  to our Newsletter

Which UPS Is Right for You?

PowerSure

UPStation GXT Mini-Tower

UPStation GXT2 Rack/Tower

Liebert Nfinity

Liebert 3 Phase

Liebert XDF High Density Cooling

Liebert Foundation Cooling w/ UPS

Liebert Flywheel Solution

Replacement Batteries

Misc. Reconditioned UPSs

Reconditioning Service

Send to a Friend

 

AddThis Social Bookmark Button

 

 

 

 

 

 

 

 

Secure Power Home Page

Our Liebert Home Page

Subscribe  to our Newsletter

Which UPS Is Right for You?

PowerSure

UPStation GXT Mini-Tower

UPStation GXT2 Rack/Tower

Liebert Nfinity

Liebert 3 Phase

Liebert XDF High Density Cooling

Liebert Foundation Cooling w/ UPS

Liebert Flywheel Solution

Replacement Batteries

Misc. Reconditioned UPSs

Reconditioning Service

Send to a Friend

 

AddThis Social Bookmark Button

Liebert UPStation GXT Run Times

Liebert UPStation GXT Run Times

Battery discharge times are at 25o C ambient.


UPStation GXT Internal Battery Run Times (minutes)
Load %700MT1000MT1000RT1000RTE1500RT2000RT3000RT
10%52959517080160101
20%384646128408351
30%30333395294728
40%23262670213420
50%16191950152715
60%12141437112112
70%1012122991810
80%899247158
90%788206137
100%577185116



UPStation GXT Internal Battery + 1 External Battery Cabinet (minutes)
Load %700MT1000MT1000RT1000RTE1500RT2000RT3000RT
10%n/an/a479554408343273
20%n/an/a255337215204140
30%n/an/a15021212513378
40%n/an/a1101549510057
50%n/an/a85116757744
60%n/an/a6689576035
70%n/an/a5673485030
80%n/an/a4863404326
90%n/an/a4153353622
100%n/an/a3546293118



UPStation GXT Internal Battery + 2 External Battery Cabinets (minutes)
Load %700MT1000MT1000RT1000RTE1500RT2000RT3000RT
10%n/an/a848923718623444
20%n/an/a425507365345236
30%n/an/a243305208211138
40%n/an/a196240164156100
50%n/an/a16819913912075
60%n/an/a1331561129459
70%n/an/a109126948150
80%n/an/a89104787043
90%n/an/a7789686236
100%n/an/a6677585431


For more information on Liebert UPSs and Products, or to read instruction manuals and technical specs, click here or paste the following URL into your browser:

http://www.liebert.com/products/lieb0002.asp


The information listed above is from the Liebert website and is Copyright © 2007 Liebert Corporation. A division of Emerson. Used with permission.

or IM me at AOL Instant Messenger (AIM):  Bruce 3PG


"It's better to be a year too early than one minute too late."

BPSF Logo

For more information call:
Bruce Hopkins
B P S F
1715 CR 2540
Quinlan, Texas 75474

(903) 751-0921
(903) 356-6233 - fax

http://www.secure-power.com . . . Rev. January 31, 2008

.

§